Fast Coal Calorimeter
ASTM D240 High Precision Microcomputer
Automatic OxygenBomb Calorimeter
BXT-ZDHW -9b
Scope of application:
The automatic calorimeter is suitable for measuring the power of coal, metallurgy,
petrochemical, quality inspection, environmental protection cement, papermaking, geological
exploration, scientific research institutes and other industrial sectors. Measuring the calorific
value of coal, coke, petroleum, cement, brick and other solid or liquid combustibles, in line
with the national standard GB/T213-2008 "calculation method of coal calorific value"
​
Product advantages:
1. The environment adaptability is strong and the test results are accurate and stable.
2. The experimental data full curve tracking function, can easily view the temperature and
time in the curve.
3. With instructions for operation, failure, etc., the experiment ends with automatic voice
report results.4. The window display uses a 7.0-inch color LCD touch screen, the display content is intuitive
and easy to understand.
5. Simple and convenient, the control core uses ARM9 microprocessor, fast, real-time.
6. Reliability fault self-tuning function, the device has a variety of protection functions.
7. Using internal and external tube photoelectric isolation, strong anti-interference ability.
8. Internal loading has standards, instructions and common troubleshooting methods.
Working principle:
Using advanced single-chip system, the operation is fully automated. All the labor needs to
do is to weigh, load and oxygenate. The instrument automatically completes the quantitative
water injection, automatic mixing, ignition, output printing results, drainage, etc. In the
calorimetric system of the calorimeter, in addition to the heat absorbed by the water, the
oxygen bomb, the inner cylinder, the thermometer and the agitator absorb heat, and the
respective heat absorption conditions are different. Various factors are complicated, and it is
impossible to rely on simple Mathematical calculations can only use the reference of known
calorific value, such as benzoic acid, to actually calibrate the heat absorbed by the
calorimeter system for every 1 °C increase, that is, to calibrate the calorimeter's heat
capacity.
​
Features:
Ultra-large capacity water tank for large batch continuous 24 hour experiment
1. The user only needs to install the oxygen bomb when the user operates, and the remaining
electronic balance is used to read the sample weight, oxygen, oxygen bomb, oxygen bomb,
quantitative inner cylinder water, ignition, completion test, oxygen bomb deflation,
experiment Results statistics and other processes can be fully automated.
2. Automatically adjust the temperature difference between the inner and outer cylinders to
ensure that the inner cylinder is about 1K higher than the outer cylinder temperature at the
end point, which fully meets the requirements of the national standard 8.2.4, and the test
results are stable for a long time.
3. It can carry out experiments for more than 72 hours, which solves the technical problem
that the calorimeter without cooling device needs to suspend the experiment due to the
increase of the outer cylinder water temperature (overshoot).
4. Imported mechanical parts, automatic oxygenation, automatic deflation, automatic lifting
oxygen bombs and other sports.
5. The compressor cooling and special heating device are adopted to realize the automatic
control of the water temperature of the outer cylinder, and the temperature control accuracy
meets the requirements of the national standard 7.1.4 (±0.1K).
6.Size(mm):600*500*425
7.Weight (kg): 65
​